Setup Pages and Descriptions
62
NXD-430/435/435P 4.3” Wall/Flush Mount Touch Panels
System Settings - Master Tab
The Master tab of the System Settings page contains the necessary information for connecting to the network
Master.
FIG. 61 System Settings page - Master Tab
System Settings Page - Master Tab
Connection Status
icon:
Shows the current state of the panel’s connection to the Master (green = online, red =
offline). See the Connection Status Icon section on page 48 for details.
Type: This display-only field indicates whether the NetLinx Master communicates with the
panel via either USB or Ethernet. This is based on the cable connection from the rear.
Note: ICSNet is not a supported option on this panel.
Ethernet is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector) used
to network computers together and is used in most LAN (local area networks). This
description is also used to refer to both wired and wireless communication.
USB option cannot be used on Modero panels that are not equipped with a USB
port.
Mode: Cycles between the different connection modes (URL, Listen, and Auto)
(ETHERNET Only - disabled when USB is selected)
URL - In this mode, enter the IP/URL, Master Port Number, and username/
password (if used) on the Master.
The System Number field is read-only because the panel obtains this information
from the communicating Master.
Listen - In this mode, add the Modero panel address into the URL List in NetLinx
Studio and set the connection mode to Listen. This mode allows the Modero touch
panel to "listen" for the Master’s communication signals.
The System Number and Master IP/URL fields are red-only.
Auto - In this mode, enter the System Number and a username/password (if
applicable). This mode is used when both the panel and the NetLinx Master are on
the same Subnet and the Master has its UDP feature enabled.
The Master IP/URL field is read-only.
System Number: Allows you to enter a system number. Default value is 0 (zero).
(ETHERNET Only - disabled when USB is selected)
Master IP/URL: Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only - disabled when USB is selected)
Master Port Number: Enters the port number used with the NetLinx Master.
Default value is 1319. (ETHERNET Only - disabled when USB is selected)
Username/Password: If the target Master has been previously secured, enter the alphanumeric string (into
each field) assigned to a pre-configured user profile on the Master.
This profile should have the pre-defined level of access/configuration rights.
Back: Saves any changes and returns to the previously active touch panel page.