Programming
96
NXD-430/435/435P 4.3” Wall/Flush Mount Touch Panels
"^" Button Commands (Cont.)
^GRD Change the bargraph ramp-down time in 1/10th of a second.
Syntax:
"'^GRD-<vt addr range>,<bargraph ramp down time>'"
Variables:
variable text address range = 1 - 4000.
bargraph ramp down time = In 1/10th of a second intervals.
Example:
SEND_COMMAND Panel,"'^GRD-500,200'"
Changes the bargraph ramp down time to 20 seconds.
^GRU Change the bargraph ramp-up time in 1/10th of a second.
Syntax:
"'^GRU-<vt addr range>,<bargraph ramp up time>'"
Variables:
variable text address range = 1 - 4000.
bargraph ramp up time = In 1/10th of a second intervals.
Example:
SEND_COMMAND Panel,"'^GRU-500,100'"
Changes the bargraph ramp up time to 10 seconds.
^GSC Change the bargraph slider color or joystick cursor color.
Syntax:
"'^GSC-<vt addr range>,<color value>'"
Variable:
variable text address range = 1 - 4000.
color value = Refer to the RGB Values for all 88 Basic Colors table on page 79.
Example:
SEND_COMMAND Panel,"'^GSC-500,12'"
Changes the bargraph or joystick slider color to Yellow.
• Colors can be set by Color Numbers, Color name, R,G,B,alpha colors (RRGGBBAA)
and R, G & B colors values (RRGGBB).
• Refer to the RGB Values for all 88 Basic Colors table on page 79.
Comments to this Manuals