Upgrading Modero Firmware
45
NXD-430/435/435P 4.3” Wall/Flush Mount Touch Panels
4. If the panel firmware being used is not current, download the latest Kit file by first logging in to
www.amx.com and then navigate to Tech Center > Firmware Files and from within the Modero section
of the web page locate your Modero panel.
5. Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you have
downloaded the Modero Kit file to a known location.
6. From within Studio, select Tools > Firmware Transfers > Send to NetLinx Device from the Main menu
to open the Send to NetLinx Device dialog (B in FIG. 46). Verify the panel’s System and Device number
values match those values listed within the System folder in the OnLine Tree tab of the Workspace
window (A in FIG. 46).
7. Select the panel’s Kit file from the Files section.
8. Enter the Device value associated with the panel and the System number associated with the Master listed
in the OnLine Tree tab of the Works pace window. The Port field is greyed-out.
FIG. 45 NetLinx Workspace window (showing the panel connection via a Virtual NetLinx Master)
Showing the Virtual Master
firmware version and
device number
Showing the current Modero
panel firmware version and
device number
Shows NetLinx Studio
version number
The panel firmware is shown on the right of the listed panel.
Download the latest firmware file from www.amx.com and then save the Kit file to
your computer.
FIG. 46 Using USB for a Virtual Master transfer