Upgrading Modero Firmware
43
NXD-430/435/435P 4.3” Wall/Flush Mount Touch Panels
5. Only after the unit displays the first panel page should the mini-USB connector be inserted into the USB
Port on the panel. It may take a minute for the panel to detect the new connection and send a signal to the
PC, indicated by a green System Connection icon.
If a few minutes have gone by and the System Connection icon still does not turn green, complete the
procedures in the following section to set up the Virtual Master and refresh the System from the Online
Tree. This action sends out a request to the panel to respond and completes the communication, turning
the System Connection icon green.
6. Navigate back to the System Settings page.
Step 2: Prepare NetLinx Studio For Communication Via the USB port
1. Launch NetLinx Studio (default location is Start > Programs > AMX Control Disc > NetLinx Studio).
2. Select Settings > Master Communication Settings to open the Master Communication Settings dialog
(FIG. 42).
3. Click Communications Settings to open the Communications Settings dialog (FIG. 43).
4. Click the NetLinx Master option under Platform Selection.
5. Click on the Virtual Master option under Transport Connection Option section to configure the PC to
communicate directly with a panel. Everything else, such as the Authentication, is disabled because the
communication is not going through the Master’s UI.
Remember that the panel’s connection type must be set to USB prior to rebooting the
panel and prior to inserting the USB connector.
FIG. 42 NetLinx Studio - Master Communication Settings dialog
FIG. 43 NetLinx Studio - Communication Settings dialog