Setup Pages and Descriptions
56
NXD-430/435/435P 4.3” Wall/Flush Mount Touch Panels
Protected Setup Page
The Protected Setup page (FIG. 56) centers around the properties used by the panel for proper communication
with the NetLinx Master. Enter the factory default password (1988) into the password keypad to access this
page. Refer to the Password Page section on page 67 for more information.
Protected Settings Page Icons
Unlike other touch panel interfaces, the interface for the Protected Settings page includes buttons featuring
icons instead of text. These button icons include:
System Settings: Press this button to configure communication settings between the NetLinx
Master and the panel (see page 60).
Calibrate: Press this button to access the Calibrate Page (see page 64).
G4 Web Control (page 65): Press this button to enable or disable remote display and control of the
panel via a Web-enabled PC.
Passwords: Press this button to access the Passwords Page (see page 67).
Panel Statistics: Press this button to access the Panel Statistics Page (see page 68).
Connection Utility: Press this button to access the Connection Utility Page see (page 71).
The elements of the Protected Setup page are described in the table below:
FIG. 56 Protected Setup Page
Protected Setup Page
Connection Status
icon:
Shows the current state of the panel’s connection to the Master (green = online, red =
offline). See the Connection Status Icon section on page 48 for details.
Device Information: • Number: Opens a keypad that is used to set and display the current device
number.
• Name: Opens a keypad that is used to set and display the current device name.
• Sync Names: Press this button to synchronize device names reserved by the
Master.
Reboot: Press this button to restart the panel after saving any changes.
Reset Settings: Press this button to wipe out all current configuration parameters on the touch panel
(such as IP Addresses, Device Number assignments, Passwords, and other presets).
• Pressing this button launches a Confirmation dialog which asks to confirm your
selection.
• This dialog is configured with a delay timer that does not enable the YES button
for 5 seconds. This delay provides an additional amount of time for the user to
confirm a decision.
System Settings
Panel Statistics
Calibrate
Passwords
Connection Utility
Return to the Setup Page
G4 Web Control
Comments to this Manuals