AMX NXD-430-WH Specifications Page 102

  • Download
  • Add to my manuals
  • Print
  • Page
    / 146
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 101
Programming
90
NXD-430/435/435P 4.3” Wall/Flush Mount Touch Panels
"^" Button Commands (Cont.)
^BMP Assign a picture to those buttons with a defined address range.
Syntax:
"'^BMP-<vt addr range>,<button states range>,<name of bitmap/picture>'"
Variables:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
name of bitmap/picture = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BMP-500.504&510.515,1,bitmap.png'"
Sets the OFF state picture for the buttons with variable text ranges of 500-504 & 510-515.
^BNC Clear current TakeNote annotations.
Syntax:
"'^BNC-<vt addr range>,<command value>'"
Variables:
variable text address range = 1 - 4000.
command value = (0= clear, 1= clear all).
Example:
SEND_COMMAND Panel,"'^BNC-973,0'"
Clears the annotation of the TakeNote button with variable text 973.
^BNN Set the TakeNote network name for the specified Addresses.
Syntax:
"'^BNN-<vt addr range>,<network name>'"
Variables:
variable text address range = 1 - 4000.
network name = Use a valid IP Address.
Example:
SEND_COMMAND Panel,"'^BNN-973,192.168.169.99'"
Sets the TakeNote button network name to 192.168.169.99.
^BNT Set the TakeNote network port for the specified Addresses.
Syntax:
"'^BNT-<vt addr range>,<network port>'"
Variables:
variable text address range = 1 - 4000.
network port = 1 - 65535.
Example:
SEND_COMMAND Panel,"'^BNT-973,5000'"
Sets the TakeNote button network port to 5000.
Page view 101
1 ... 101 102 103 ... 146

Comments to this Manuals

No comments