Troubleshooting
121
NXD-430/435/435P 4.3” Wall/Flush Mount Touch Panels
Troubleshooting
This section describes the solutions to possible hardware/firmware issues that could arise during the common
operation of a Modero touch panel.
Troubleshooting Information
Symptom Solution
My USB drivers has a yellow
exclamation point and doesn’t
appear to be working.
The USB driver was incorrectly installed and should be re-installed:
• Power up the panel without the USB cable connected to the panel.
• Plug in the USB cable into the G4 panel. You should see a USB icon
show up in the System Tray.
• Double click on the icon to bring up the list of USB devices (you should
see the "AMX USB LAN LINK" device in the list).
• If the "Install Driver" dialog doesn't appear automatically, select the
"Properties" button and then the "Update Driver" button.
• When the Install Driver dialog does appear, click Next to accept all the
default prompts.
• The OS will state that the driver you are installing/updating does not
have a digital signature. This is acceptable, so agree to continue the
installation.
• After installation is complete, the exclamation point should disappear.
When using G4 WebControl to
communicate with a target panel,
a VNC Server dialog appears on
my screen.
• During a WebControl connection to a target panel, a G4 Authentication
dialog will ask you to enter the assigned password for the panel before
allowing access.
• If prompted with a VNC Server dialog, enter the IP Address of the target
panel. This can be found within the Setup > Protected Setup >
System Connection page. This IP Address of the panel appears within
the IP Settings section of this page
• Enter the IP Address and click OK. When prompted with the G4
Authentication popup, enter the panel’s WebControl password.
While attempting to communi-
cate directly with the Virtual
Master (on the PC) via a USB
connection, I can’t get my com-
munication icon to turn Green.
• A Green communication icon indicates that a connection has been
established to the target Master or target Virtual Master.
• Launch NetLinx Studio and configure the Master Connection
communication settings for a Virtual Master.
• Navigate to the System connection page and toggle the Type field to
USB.
• Make sure the Type-A USB connector is securely connected to the PC.
• Make sure the panel DOES NOT have the mini-USB connected and
then TURN OFF the panel.
• Once the panel has turned ON, THEN connect the mini-USB to the
Program Port. The USB icon should appear in the system tray. If it
doesn’t, refer to the Configuring and Using USB with a Virtual
Master section on page 25.
• The panel may need a few minutes to detect the connection to the PC.
My Modero panel isn’t appearing
in my Workspace window.
• Verify that the System number is the same on both the NetLinx
Workspace window and the System Connection page on the Modero
panel.
• Verify that you have entered the proper NetLinx Master IP and
connection methods into the Master Connection section of the System
Connection page.