10. Glossary
Rain Bird
®
ET Manager Series - Installation and Operation Manual 73
10. Glossary
Accuracy: The ET Manager looks at the last two weeks
of weather signals and reports the accuracy of the
weather signal. An accuracy level less than 65% will
create an attention condition.
Attention Indicator Light: A yellow light signals a con-
dition that you should be aware of. An attention mes-
sage is displayed on the Home screen.
Automatic Mode: Automatic mode is the standard
Control Mode setting. In this mode all automatic func-
tions are active and your ET Manager will operate as
programmed.
Automatic Window: The Automatic Window is pro-
grammed to match the first start time programmed in
your sprinkler controller, and to stay open until your
sprinkler controller has completed watering all cycles.
A status message on the Home screen indicates when
the Automatic Window is open. Watering is either
interrupted or enabled during the Automatic Window.
If watering is enabled (Valve Indicator Light(s) is green),
a current sensor is used to verify that the sprinkler con-
troller operates during the time period.
Available Watering Days: The days available for
watering are programmed in your ET Manager or
your sprinkler controller. Typically Available Watering
Days are set to all” or everyday.
Clear Data: The ET Manager stores two weeks of
weather signal data. Records can be cleared if needed.
Clearing the data will erase all of the stored data.
Clearing data will also reset moisture levels to zero.
Clearing Data will not change any settings.
Control Mode: Normally your ET Manager should be
set to operate in the Automatic mode. Other modes
include Disabled and Historical ET. This menu allows
you to select the control mode.
Crop Coefficients (Kc): A factor percentage to modify
ET
OS
based on a specific plant type. It is used to adjust
an ET value to meet the specific needs of a plant, ET
OS
x K
C
= ET
C
. There are both local and seasonal varia-
tions in K
C
values.
Cursor: The “
symbol indicates the current cursor
location.
Daily Window: The Daily Window is a period of time
programmed in your ET Manager corresponding to the
time period the sprinkler controller is programmed to
water BUT NOT based on ET control. Watering is
allowed every day during the Daily Window. When the
Daily Window “opens” it enables or allows watering on
both Valve Groups A and B. The Daily Window period
operates outside the Automatic Window.
Decoder Failure: Your ET Manager uses signal decoder
to receive the weather signal. The Attention Light will
come on and “Decoder Failure” will appear if your ET
Manager is experiencing decoder problems.
Disabled Mode: The ET Manager can be disabled. This
can be selected from the Control Mode menu. When
Disabled all automatic functions are suspended. The
weather signal will continue to be received and logged,
ET will be calculated, while all outputs are disabled and
the indicator lights will be off.
Effective Rain Settings: Effective rain is the amount of
rain that is an effective or available source of water for
the plant. When rainfall amounts and intensities are
extreme, not all rainfall will stay within the root zone.
To restrict the amount of rain recognized by the system,
two effective rainfall limits should be programmed:
Max Hourly Rain and Saturation Allowance (see defini-
tions for Max Hourly Rain and Saturation Allowance).
Elevation: Your ET Manager uses elevation above sea
level when calculating ET.
Enable: The ET Manager uses this Output Method to
control the days a sprinkler controller is allowed to water.
It will enable watering when it is needed. This mode
bypasses the common output of the controller.