ET Manager Series - Installation and Operation Manual 12
Wire Connection Guidelines
Strip approximately
1
4” insulation off the ends
of wires connected to the ET Manager, and
strip insulation off the ends of other wires as
needed.
Use an appropriate screwdriver for all mount-
ing.
Use a thin blade screwdriver for all ET Manager
wire terminal connections.
Use appropriate screwdriver for all wire con-
nections to sprinkler controller.
Use proper wire gauges, 14-26 AWG for termi-
nal connections, and 10-18 AWG for
grounding.
Use proper wire ties.
Verify each wire connection is secure.
Use a Volt-Ohm meter to test and verify com-
mon wires and power source voltage.
WARNING: To prevent electrical shock make sure the
power supply is OFF before connecting wires to any of
the devices. Electrical shock can cause severe injury or
death.
Grounding
Connect a 10, 12, 14 or 18-gauge ground wire to earth
ground. Strip approximately 1/4" insulation from the
end of the ground wire and connect to the ET Manager
ground connection using a thin blade screwdriver. Give
the wire a gentle tug to verify it is secure.
GROUNDING IS ESSENTIAL for electrical surge pro-
tection and personal protection.
Note: 10 AWG is preferred for grounding your ET
Manager.
Power
WARNING: To prevent electrical shock, damage to the
ET Manager, or damage to your sprinkler controller,
make sure the power supply is OFF before connecting
wires to any of the devices. Electrical shock can cause
severe injury or death.
All electrical connections and wire runs must be made
in accordance with local building codes.
The power requirement is 12 to 30-volts AC or 12 to 35-
volts DC and draws a maximum 0.22 (0.2) Amp max.
Power for the ET Manager can come from one of two
sources:
Power Option 1
The ET Manager can be connected to a 24-volt AC
source within the sprinkler controller. The current
draw is 0.22 (0.2) Amps (less than one standard valve
solenoid). Check the sprinkler controller owners man-
ual to verify that accessory devices can be powered
from the sprinkler controller power supply.
Connect a 14 or 18 AWG wire to the sprinkler controller
24-volt AC power supply. Strip approximately
1
4" insu-
lation from the ends of the power wires. Using a thin
blade screwdriver, connect the wires to the ET Manager
power terminals labeled “24 VAC.” Give the wires a gen-
tle tug to verify they are secure.
Power Option 2
Use a Rain Bird ETMi 120-volt AC Plug-in Transformer
635640 (Model ETMi-TRAN). Using a thin blade screw-
driver, attach the two orange wire ends of the trans-
former to the 24-volt AC wire terminals on the ET
Manager wire terminal strip. If an adequate ground is
not connected, as described above, attach the green
ground wire, to the ET Manager ground connection
using a thin blade screwdriver. Give the wires a gentle
tug to verify they are secure. Plug power supply into a
120-volt AC outlet.