5. In the Edit Options window of the AMX Library Files dialog, click Import Hex File to access the Hex data import
and conversion options (FIG. 80).
6. Enter the name of the function that you want to import, in the Enter Function text field.
7. Copy and paste the appropriate Hex code for this function in the Import Data text field (see the Importing IR HEX
File Codes section on page 48).
8. Click the Convert button to convert the Hex code and add it to the selected IR Library.
Testing IR Functions
It is recommended that all IR functions are tested before being written into program scripts:
1. In the AMX IR Libraries dialog, select the function to test from the Function drop-down menu (FIG. 84).
2. Connect an IR Transmitter to the ControlPad’s IR Port, and place the IR Emitter directly in front of the device’s IR
receiver.
3. Click the TEST button, and verify that the device responded appropriately.
If the device does not respond correctly, click the Edit Data button (in the Edit Options window) to access the IR Data
for the selected function, to view and edit (FIG. 85):
The main reason that a device will not respond is that the transmit frequency needs adjustment.
Try increasing or decreasing the frequency to the next value by clicking on the Fine Tune arrow buttons.
Also, try adjusting the Pulses/Bit value. Click on TEST to re-test the function (FIG. 86).