AMX AXD-CP Specifications Page 52

  • Download
  • Add to my manuals
  • Print
  • Page
    / 70
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 51
AMX Novara DCS1000 Device Configuration Software
48
Novara ControlPads & KeyPads
6. Connect the IRIS to your PC:
a. Connect an RS-232 cable to the DB-9 connector on the IRIS unit and an RS-232 port on your PC.
b. Set the baud rate in the IRIS unit to match the PC baud rate.
c. Then, connect the 12 VDC or 12 VAC power supply to the 12 VDC connector on the IRIS unit.
d. The READY LED lights and 01 appears in the display.
7. Enter a function name in the Enter Function text field.
8. Learn the code from the remote controller:
a. Hold the remote approximately 3-inches away from the IR capture window. Press and hold the first key on the
HC to capture the first function. The
SIGNAL LED will start blinking. Release the HC key as soon as the READY
LED goes off.
b. The [ ] briefly appears in the display to indicate the HC function is captured. Then, 01 appears and the READY
and VERIFY LEDs light. The LED will not light if P4 mode is active.
c. Hold the HC device approximately 3-inches away from the IR capture window. Press and hold the same key on
the HC device again to verify the IR function was captured correctly by the IRIS unit. If the HC function is
captured correctly, a pair of [ ] (brackets) will briefly flash in the display. The VERIFY LED goes off, 01 appears
in the display, and the
SEND pushbutton's LED lights. If an Er message appears in the display, repeat steps 3 and
5. Otherwise, go to step 6.
d. Press the SEND pushbutton to send the captured HC function to the PC running the IREdit software program.
e. Repeat steps C through E to capture all the HC functions on your list.
9. Click on Capture then press the Send button on the front panel of the IRIS. The function will be added to the current
device library.
Refer to the IREdit instruction manual for information on to storing captured HC functions.
Importing IR HEX File Codes
Alternatively, IR Libraries can be created by importing IR HEX file codes.
1. In the Edit Options window of the AMX Library Files dialog, click Import Hex File to access the Hex data import
and conversion options (FIG. 80).
FIG. 79 AMX IR Library dialog - Learn New Functions fields
AMX does not provide HEX codes, and therefore, cannot give any assurance that
data provided by others is accurate or functional. There are a number of web sites
that make IR HEX codes freely available. One such site is Remote Central, where
you can search for your specific device and look for downloads with "text files with
HEX codes".
Page view 51
1 ... 51 52 53 ... 70

Comments to this Manuals

No comments