AMX NI-2000 Instruction Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 134
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
Introduction
3
NetLinx Integrated Controllers
NI-2000 Specifications (Cont.)
Front Panel Components:
LINK/ACT Green LED lights when the Ethernet cable is connected and an active link
is established. This LED also blinks when receiving Ethernet data packets.
Status Green LED lights to indicate that the system is programmed and
communicating properly.
Output Red LED lights when the Controller transmits data, sets channels On/Off,
sends data strings, etc.
Input Yellow LED blinks when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
RS-232/422/485 LEDs Three sets of red and yellow LEDs light to indicate the rear DB9 Ports 1-3
are transmitting or receiving RS-232, 422, or 485 data:
- TX LEDs (red) light when transmitting data
- RX LEDs (yellow) light when receiving data
- LED activity reflects transmission and reception activity
Relay LEDs Four red LEDs light to indicate the rear relay channels 1-4 are active
(closed).
These LEDs reflect the state of the relay on Port 4
If the relay is engaged = LED On and if the relay is Off = LED Off
IR/Serial LEDs Four red LEDs light to indicate the rear IR/Serial channels 1-4 are
transmitting control data on Ports 5-8
LED indictor for each IR port remains lit for the length of time that IR/Serial
data is being generated
I/O LEDs Four yellow LEDs light when the rear I/O channels 1-4 are active
LED indicator for each I/O port reflects the state of that particular port
Rack-mount brackets Provide an installation option for the Integrated Controller to be mounted
into an equipment rack.
Rear Panel Components:
RS-232/422/485 (Ports 1 -3) Three RS-232/422/485 control ports using DB9 (male) connectors with
XON/XOFF (transmit On/transmit Off), CTS/RTS (clear to send/ready to
send), and 300-115,200 baud.
Channel range = 1-255
Channels 1-254 provide feedback
Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a
'CTSPSH' command was sent to the port
Output data format for each port is selected via software
Three DB9 connectors provide RS-232/422/485 termination
ICSNet Two RJ-45 connectors for ICSNet interface
ICSHub Out Single RJ-45 connector provides data to another Hub connected to the
Controller
Relay (Port 4) Four-channel single-pole single-throw relay ports
Each relay is independently controlled.
Supports up to 4 independent external relay devices
Channel range = 1-4
Each relay can switch up to 24 VDC or 28 VAC @ 1 A
One 8-pin 3.5 mm mini-Phoenix (female) connector provides relay
termination