Configuration and Firmware Update
38
NetLinx Integrated Controllers
6. Click the Edit Settings button to open the Serial Settings dialog (FIG. 23).
7. Set the COM port parameters for the selected COM port used for communication to the
NetLinx Master. Default parameters are: COM1, 38400, 8 Data Bits, No Parity, 1 Stop Bit,
and No Flow Control. If communication fails on a known COM port, change the baud rate
to 115200 and try again.
8. Click OK three times to close the open dialogs and save your settings.
Setting the System Value
1. Access/open the Device Addressing dialog box (FIG. 24) by either one of these two methods:
Right-click on any System item listed in the OnLine Tree tab of the Workspace and
select Device Addressing (from the pop-up list).
Select Diagnostics > Device Addressing from the Main menu.
FIG. 23 Assigning Communication Settings and Baud Rates
The default setting for these
units is 38400
If the connection fails to establish:
Select a different COM port, press the Retry button to reconnect using the same
communication parameters, or press the Change button to alter your communication
parameters and repeat steps 2 thru 8.
FIG. 24 Device Addressing tab (changing the system value)
System Address
(default for initial
system is 1)
Check-Off to
verify change