Installation and Wiring
11
NXC-ME260 NetLinx Master-Ethernet Card/Module
FIG. 4 diagrams the RJ-45 cable and connectors.
SPE Port Connection/Wiring
Use an RJ-11 cable to connect the NXC-ME260 to an AXB-SPE Slave Port Expander.
The
EXPANSION OUT port on the rear panel of the NXC-ME260 connects to the EXPANSION IN
port on the rear panel of the AXB-SPE (FIG. 5).
You can daisy chain multiple AXB-SPE's by connecting the
EXPANSION OUT on the primary
AXB-SPE to the
EXPANSION IN port on the secondary, as shown in FIG. 6. The connecting RJ-11
cable should not exceed 6" in length. Repeat this process to connect up to nine AXB-SPE's.
FIG. 4 RJ-45 wiring diagram
FIG. 5 AXB-SPE (rear panel)
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RJ-45
Plug
RJ-45
Plug
EXPANSION IN port (RJ-11)