Appendix B – Programmer’s Interface for System Diagnostics
63
Optima SD Instruction Manual
Appendix B – Programmer’s Interface
for System Diagnostics
System Component Information
The Optima SD displays system information in its splash screen* for diagnostic purposes. The
information indicates the current status and well-being of the system components.
The splash screen can be accessed using a terminal emulation program, such as HyperTerminal
(see page 30). One of four verbosity** settings is specified, which provides either a list of the five
system components with minimal information (FIG. 34) or a level of detailed information on one of the
five components. Only one verbosity setting and one component setting can be entered in a command.
The order in which the verbosity and component settings are entered is interchangeable.
Note: In a multi-enclosure system, the splash screen displays information only for the enclosure that
is connected directly to the PC.
* AMX reserves the right to add to the contents of the splash screen at any time, without notice.
** Verbosity (i.e., wordiness) refers to the amount of information provided; the higher the verbosity
setting, the more information is displayed.
FIG. 34 Example of Optima SD splash screen
Command entered to display minimal
information for all system components
The system’s component identity numbers
are to the left of each component
~scr!
[1:Enclosure] AutoPatch Optima
[2:Storage Blocks] cleared
[3:Communication Interfaces] count = 3
[4:Hardware Boards] detected
[5:VM Configuration] count = 3