AMX AXP-AI8 ANALOG 8-INPUT BOARD Instruction Manual Page 58

  • Download
  • Add to my manuals
  • Print
  • Page
    / 70
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 57
Appendix A - Telnet (Terminal) Commands
48
Instruction Manual - Solecis Digital Switchers
Setting a Telnet Username and Password
Perform these steps to set a Telnet username and password:
1. Establish a terminal connection via Telnet.
2. Type Set Telnet Username, and press Enter.
The program will prompt you to enter a new Telnet username; enter a username and press Enter.
The program will indicate that the username is being stored.
3. Type Set Telnet Password, and press Enter.
The program will prompt you to enter a password; press Enter twice to clear both the Telnet username and
password.
Enter a password and press Enter.
The program will prompt you to re-enter the password; re-enter the password and press Enter.
The program will indicate that the password is being stored.
Telnet Commands
The Telnet commands listed in the table below can be sent directly to the switcher via a Telnet terminal session.
The default Telnet port is 23. A value of 0 (zero) disables the Telnet server.
Telnet is enabled by default.
In the terminal program, type Help or a question mark (?) and press Enter to access the Help Menu and display the
terminal commands described in the table below.
Telnet Commands
Command Description
? or Help Display the commands listed in this table.
DEVICE STATUS Displays device status of a specified device, port, system (<D:P:S>).
Note: Devices other than the switcher itself will be ignored.
Example:
>device status 32002:1:0
Device Status
-------------
Device 1123 AMX LLC, SDX-510M-DX, v99.86.00 contains 17 Ports
Port 1 - Channels:255 Levels:0
MaxStringLen=64 Types=8 bit MaxCommandLen=64 Types=8 bit
The following output channels are on:None
>
DIPSWITCH Displays the current value for each of the DIP switch’s four toggles.
Example:
>dipswitch
Dipswitch - ON OFF OFF OFF
>
EXIT Exit the Telnet session.
FACTORYFWIMAGE Resets unit to factory firmware image and reboots the switcher.