AMX NXD-500i Specifications Page 55

  • Download
  • Add to my manuals
  • Print
  • Page
    / 154
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 54
Upgrading Modero Firmware
43
NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom
7. Enter the System number (default is 1).
8. Click OK three times to close the open dialogs, save the settings, and return to the main NetLinx Studio
application.
9. Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System.
The default System value is one.
10. Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list.
The panel will not appear as a device below the virtual system number in the Online Tree tab until both
the system number used in step 7 for the Virtual NetLinx Master (VNM) is entered into the Master
Connection section of the System Settings page.
Step 3: Confirm and Upgrade the firmware via the USB port
Use the CC-USB Type-A to Mini-B 5-wire programming cable (FG10-5965) to provide communication
between the mini-USB Program port on the touch panel and the PC. This method of communication is used to
transfer firmware Kit files and TPD4 touch panel files.
1. Verify that the direct USB connection (Type-A on the panel to mini-USB on the panel) is configured
properly using the steps outlined in the previous two sections.
2. After the Communication Verification dialog window verifies active communication between the Virtual
Master and the panel, click the OnLine Tree tab in the Workspace window (FIG. 36) to view the devices
on the Virtual System.
The default System value is one.
3. Right-click on the System entry (FIG. 36) and select Refresh System to re-populate the list.
Verify the panel appears in the OnLine Tree tab of the Workspace window.
The default Modero panel value is 0.
FIG. 35 Virtual NetLinx Master Settings dialog
If the G4 panel does not appear, refer to the Troubleshooting section on page 129 for
more information.
A mini-USB connection is only detected after it is installed onto an active panel. This
allows the PC to detect the panel and assign an appropriate USB driver.
Page view 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 153 154

Comments to this Manuals

No comments