22 Installation Guide CA-10 plus SATEL
The keypads are not be connected in parallel to one CLK signal (one partition - two
keypads), with the exception of the CA-10 KLED keypads. The other LCD keypads
as well as the CA-10 KLED-M and CA-10 KLED-S keypads must not be connected in
parallel.
The keypad anti-tampering contact has no connection with the system anti-tampering
circuit. Its state is defined by the control panel, based on the data received from the
keypad. When the control panel is in the service mode, the anti-tampering contact is
not controlled.
Connection of Zone Expander
In order to increase the number of zones, a zone expander can be connected,
instead of a full set of
keypads. It makes
available the zones of
keypads required for full
configuration. The
expander should be
connected as a next
keypad. It can be used in
combination with a
different number of
keypads.
Figure 5 shows how the
expander is connected to
the CA-10 plus control
panel.
The jumpers A, B, C, D are used for setting the expander address – the upper
position corresponds to a jumper set in the keypad. The jumpers C1 & C2 should be
set as required by the number of keypads connected to the panel. The expander
jumpers must be set in either upper or lower position - they must not be permanently
removed.
The expander TMP input is an equivalent to the keypad tamper – normally it should
be shorted to ground.
The control panel and expander can be configured in three ways:
1 keypad and expander:
• keypad connected as first keypad (CLK1)
• expander CLK connected to control panel CLK2
• jumpers C1 & C2 in upper position
• expander address programmed as second, third and fourth keypad address
in the control panel
• expander zones Z1 to Z6 available as system zones 11 to 16.
2 keypads and expander:
• keypads connected as first and second keypads (CLK1 & CLK2)
• expander CLK connected to control panel CLK3
• jumper C1 in upper position, C2 in lower position
• expander address programmed as third and fourth keypad address in the
control panel
• expander zones Z1 to Z4 available as system zones 13 to 16.
3 keypads and expander:
• keypads connected as first, second and third keypads (CLK1, CLK2 &
CLK3)
Z1 COM Z2
AUX
AUX
DATA
CLK
TMP
COM
A C1 C2
CA10E
+KPD
DATA
CLK
COM
EXPANDER HOUSING
CENTRALA
Z3 COM Z4 Z5 COM Z6
BCD
LED ON/OFF
- Zone expander.
(upper pos.)
CA10 plus
ANTI-TAMPERING CONTACT
Figure 5
CA10