Chapter 2. Architecture and technical overview 49
Draft Document for Review May 28, 2009 1:59 pm 4405ch02 Architecture and technical overview.fm
2.9.2 Split backplane
As described in paragraph 2.9.1, “Integrated RAID options” on page 48 the same features are
required to split the 6-pack DASD backplane in two groups of three disks. Using feature 3650
and 5900 disk 4,5, and, 6 are managed using the external SAS controller. Disk 1, 2, and 3 are
managed by the internal SAS controller.
2.9.3 Internal media devices
Inside each CEC drawer in the 570 there is an optional media backplane with one media bay.
The internal IDE media bay in separate CEC drawers can be allocated or assigned to a
different partition. The media backplane inside each CEC drawer cannot be split between two
logical partitions.
2.9.4 Internal hot-swappable SAS drives
The 570 can have up to six hot-swappable disk drives plugged in the physical 6-pack disk
drive backplane. The hot-swap process is controlled by the virtual SAS Enclosure Services
(VSES), which is located in the logical 6-pack disk drive backplane. The 6-pack disk drive
backplanes can accommodate the devices listed in Table 2-14
Table 2-14 Hot-swappable disk options
Prior to the hot-swap of a disk drive in the hot-swappable-capable bay, all necessary
operating system actions must be undertaken to ensure that the disk is capable of being
deconfigured. After the disk drive has been deconfigured, the SAS enclosure device will
power-off the slot, enabling safe removal of the disk. You should ensure that the appropriate
planning has been given to any operating-system-related disk layout, such as the AIX Logical
Volume Manager, when using disk hot-swap capabilities. For more information, see Problem
Solving and Troubleshooting in AIX 5L, SG24-5496.
3651 + 5900 or 5909 A hardware feature that occupies PCIe slot P1C3 provides a mini
SAS 4x connector to the rear bulkhead and allows all of the internal
SAS drives to be controlled using an external SAS controller.
Feature Description
Feature code Description
3646 73.4 GB 15,000 RPM SAS hot-swappable disk drive
3647 146.8 GB 15,000 RPM SAS hot-swappable disk drive
3548 300 GB 15,000 RPM SAS hot-swappable disk drive
Note: We recommend that you follow this procedure, after the disk has been deconfigured,
when removing a hot-swappable disk drive:
1. Release the tray handle on the disk assembly.
2. Pull out the disk assembly a little bit from the original position.
3. Wait up to 20 seconds until the internal disk stops spinning.
Now you can safely remove the disk from the DASD backplane.