Amx Modero NXT-1200V User Manual Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 178
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
Installation Procedures: NXD-1200V Panels
35
NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel
2. Verify the incoming RJ-45, Ethernet, USB, and any other audio/video cables have been properly threaded
through the wiring knockouts (from their terminal locations) on the conduit box.
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
3. Connect all data and power wiring connectors to their corresponding locations along the side of the (un-
powered) NXD touch panel.
Verify the terminal end of the power cable is not connected to a power supply before plugging in the
2-pin power connector.
The USB connectors can be from either a USB extension cable, or a wireless USB RF transmitter.
4. Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly to prevent repetition of the
installation.
5. Disconnect the terminal end of the power cable from the connected power supply.
6. Carefully slide the main unit (B in FIG. 38) into the conduit box, so the Mounting Tabs lie flush against
the conduit box (C in FIG. 38).
7. Insert and secure the four securing #4-40 Mounting Screws into their corresponding holes located along
the sides of the NXD (FIG. 37 and FIG. 38).
8. Place the magnetic faceplate (A in FIG. 38) back onto the main NXD unit (B in FIG. 38).
Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective openings
on the front bezel/faceplate.
FIG. 38 Wall Mount panel installation configuration for pre-existing conduit/wallbox in a pre-wall construction
B - Main NXD unit consists of
C - Optional CB-TP
Install the four #4-40
screws into the places
indicated
Stud
the touch panel and backbox housing
conduit/wallbox
Cable
knockouts
Installed flush
against the
finished wall
Do not use these
tabs to mount
the conduit /wallbox
These are ONLY used to
secure the main unit to the CB
SURFACE
surface
A - Faceplate
(bezel)
Mounting Tab
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the conduit box.
Page view 46
1 ... 46 47 48 ... 178

Comments to this Manuals

No comments