RGBHV/HD-15 Boards
67
Modula Instruction Manual
Attaching Cables
Important: If using RGBHV/HD-15 boards in a CatPro system – first see “RGBHV+Stereo to CatPro
Boards with TXs and RXs” starting on page 69 for special system information.
When attaching RGBHV/HD-15 input and output cables, refer to the sheet labeled “AutoPatch Modula
Connector Guide” that ships with the system. The sheet shows you where to attach each cable on the rear
of each enclosure. Follow the sheet exactly; the system was programmed at the factory to operate only as
indicated on the sheet. For multiple-enclosure systems, each enclosure will be numbered (e.g., “Chassis
1 of 3”) on a label located on the left side (near the power receptacle).
To connect RGBHV/HD-15 inputs and outputs:
1.
Fasten the cables onto the input and output HD-15 connectors (FIG. 34).
HD-15 Board Connector Pinout
For High Density DB-15 board connector pinout information, see FIG. 35.
FIG. 34 Fasten cable onto input or output HD-15 connector
FIG. 35 RGBHV/HD-15 input and output board connector pinout
Note: 55 mA supplied on output pin 9; power draw not to exceed 50 mA per port.
RGBHV/HD-15 Board Connector Pinouts
Input (VESA DDC Compliant)
1. Red 6. Red GND 11. ID Bit
2. Green 7. Green GND 12. DDC SDA
3. Blue 8. Blue GND 13. Horizontal sync
4. ID Bit 9. +5 V in DDC 14. Vertical sync
5. GND 10. GND 15. DDC SCL
Output
1. Red 6. Red GND 11. ID Bit
2. Green 7. Green GND 12. ID Bit
3. Blue 8. Blue GND 13. Horizontal sync
4. ID Bit 9. +5 V out DDC 14. Vertical sync
5. GND 10. GND 15. ID Bit