NI-3100 Specifications
Dimensions (HWD): 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)
2 rack units high
Power Requirement: 900 mA @ 12 VDC
Memory: 64 MB SDRAM
1 MB Non-volatile (NV) SRAM
Compact Flash: 128 MB or more
AMX may increase Flash size at any time in response to market availability
Upgradeable - see Other AMX Equipment
Weight: 4.55 lbs (2.06 kg)
Enclosure: Metal with black matte finish
Certifications: FCC Part 15 Class B, CE, and IEC 60950
Front Panel LEDs:
LINK/ACT: Green LED blinks when the Ethernet cables are connected and
terminated correctly. Also blinks when receiving Ethernet data
packets.
Status: Green LED blinks to indicate that the system is programmed and communi-
cating properly.
Output: Red LED blinks when the Controller transmits data, sets channels On and
Off, sends data strings, etc.
Input: Yellow LED blinks when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
RS-232/422/485: 7 sets of red and yellow LEDs light to indicate that DB9 Ports 1 - 7 are trans-
mitting or receiving RS-232, 422, or 485 data.
Relay: Eight-channel single-pole single-throw relay ports
Each relay is independently controlled.
Supports up to 8 independent external relay devices
Channel range = 1-8
Each relay can switch up to 24 VDC or 28 VAC @ 1 A
Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay
termination
IR/Serial: 8 red LEDs light to indicate the IR/Serial channels 1 - 8 are
transmitting control data on Ports 9 - 16. LED indictor for each IR port
remains lit for the length of time that IR/Serial data is being generated.
I/O: 8 yellow LEDs light when the rear I/O channels 1 - 8 are active. The LED for
each I/O port reflects the state of that particular port.
Rear Panel Components:
RS-232/422/485 (Ports 1 - 7): 7 RS-232/422/485 control ports using DB9 (male) connectors with XON/
XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and
300-115,200 baud.
ICSNet: 2 RJ-45 connectors for ICSNet interface (provided by optional
ICSNet daughter card).
ICSHub Out: RJ-45 connector provides data to a Hub connected to the Controller (pro-
vided by optional ICSNet daughter card).
Relay (Port 8): 8-channel single-pole single throw relay ports with each relay being indepen-
dently controlled and supporting up to 8 independent
external relay devices.
Digital I/O (Port 17): 8-channel binary I/O port for contact closure with each input being capable of
voltage sensing. Input format is software selectable with interactive power
sensing for IR ports.