AMX NI-3100 Specifications Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 160
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
WebConsole - Security Options
32
NetLinx Integrated Controllers- WebConsole & Programming Guide (FMv3)
Viewing Group Security Settings Details
Click on any Group listed in the Group Security Details page to expand the view to show details for the
selected user Group (FIG. 29):
Group and User Security Access Options (Cont.)
Option Description
Telnet/SSH/SFTP
Access:
If selected, a valid username and password is required for Telnet Access. Telnet access
allows communication over either the Telnet and/or SSH Ports, and Secure FTP access.
Note: SSH version 2 (only) is supported.
To establish a secure Telnet connection, an administrator can decide to disable the Telnet
Port and then enable the SSH Port. Refer to the Manage System - Server Options on
page 49.
Configuration: If selected, a valid username and password is required before allowing a group/user to
alter the current Master’s security and communication settings via NetLinx Studio.
This includes such things as: IP configuration/Reset, URL list settings, Master
communication settings, and security parameters.
ICSP Connectivity: If selected, a valid username and password is required to communicate with the NetLinx
Master via an ICSP connection (TCP/IP, UDP/IP, and RS-232).
This feature allows communication amongst various AMX hardware and software
components. This feature works in tandem with the Require Encryption option (see
below) to require that any application or hardware communicating with the Master must
provide a valid username and password.
In a Master-to-Master system, the Master which accepts the IP connection initiates the
authentication process. This configuration provides compatibility with existing
implementations and provides more flexibility for the implementation of other devices.
Note: The ICSP Connectivity option is required to allow authenticated and/or secure
communication between the Master and other AMX hardware/software. To establish an
authenticated ICSP connection (where the external AMX hardware/software has to
provide a valid username and password), this option must be enabled.
Encrypt ICSP
Connection:
If selected, this option requires that any data being transmitted or received via an ICSP
connection (among the various AMX products) be encrypted, and that any application or
hardware communicating with the Master over ICSP must provide a valid username and
password.
Note: When enabled, this option requires more processor cycles to maintain.
FIG. 29