Hardware Reference GuideNetLinx Integrated ControllersNXI-x000 SeriesNetLinx Integrated Controllers(NI-2000, NI-3000, NI-4000)Last Revised: 5/30/2008
Introduction6NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-3000 SpecificationsThe front LEDs (FIG. 3) are grouped by control type and are label
Introduction7NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-3000 SpecificationsDimensions (HWD): • 3.47" x 17.00" x 3.47" (8.81 c
Introduction8NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-3000 Specifications (Cont.)Rear Panel Connectors (Cont.):Relay (Port 8) • Eight-chan
Introduction9NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-3000 Specifications (Cont.)Rear Panel Connectors (Cont.):Ethernet Link/Activity LED
Introduction10NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-4000 SpecificationsThe front LEDs (FIG. 5) are grouped by control type, and are lab
Introduction11NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-4000 SpecificationsDimensions (HWD): • 5.21" x 17.00" x 9.60" (13.23
Introduction12NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-4000 Specifications (Cont.)Rear Panel Connectors:RS-232/422/485 (Ports 1 -7) • Seve
Introduction13NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-4000 Specifications (Cont.)Rear Panel Connectors (Cont.):Program port • RS-232 DB9
Introduction14NI-2000, NI-3000, NI-4000 Hardware Reference GuideRelated DocumentsFor information on using the on-board Web Console, as well as NetLinx
Installation and Upgrading15NI-2000, NI-3000, NI-4000 Hardware Reference GuideInstallation and UpgradingInstalling NetLinx Control Cards (NI-4000 Only
AMX Limited Warranty and DisclaimerAMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years fr
Installation and Upgrading16NI-2000, NI-3000, NI-4000 Hardware Reference GuideSetting the NetLinx Control Card Addresses (NI-4000 Only) The 8-positio
Installation and Upgrading17NI-2000, NI-3000, NI-4000 Hardware Reference GuideNUMBER:PORT:SYSTEMwhere: Removing NetLinx Control Cards (NI-4000 Only)
Installation and Upgrading18NI-2000, NI-3000, NI-4000 Hardware Reference Guide3. Carefully pull-up and remove the housing up and away from the Control
Installation and Upgrading19NI-2000, NI-3000, NI-4000 Hardware Reference Guide7. To complete the upgrade process, close and re-secure the Integrated C
Installation and Upgrading20NI-2000, NI-3000, NI-4000 Hardware Reference Guide3. Thread the cables through the opening in the equipment rack. Allow fo
Connections and Wiring21NI-2000, NI-3000, NI-4000 Hardware Reference GuideConnections and WiringSetting the Configuration DIP Switch (for the Program
Connections and Wiring22NI-2000, NI-3000, NI-4000 Hardware Reference GuideWorking With the Configuration DIP Switch1.Disconnect the power supply from
Connections and Wiring23NI-2000, NI-3000, NI-4000 Hardware Reference GuideModes and Front Panel LED Blink PatternsThe following table lists the modes
Connections and Wiring24NI-2000, NI-3000, NI-4000 Hardware Reference GuideAXlink Port and LEDAll NI units have an AXlink port and adjacent status LED
Connections and Wiring25NI-2000, NI-3000, NI-4000 Hardware Reference GuidePreparing Captive WiresYou will need a wire stripper and flat-blade screwdri
Table of ContentsiNI-2000, NI-3000, NI-4000 Hardware Reference GuideTable of ContentsIntroduction ...
Connections and Wiring26NI-2000, NI-3000, NI-4000 Hardware Reference GuideUsing the 4-pin Mini-Phoenix Connector For Data With External PowerTo use th
Connections and Wiring27NI-2000, NI-3000, NI-4000 Hardware Reference GuideThe table below provides information about the connector pins, signal types,
Connections and Wiring28NI-2000, NI-3000, NI-4000 Hardware Reference GuideICSHub OUT Port: Connections and WiringThe NI Controller must be equipped wi
Connections and Wiring29NI-2000, NI-3000, NI-4000 Hardware Reference GuideInput/Output (I/O) Port: Connections and WiringThe I/O port responds to eith
Connections and Wiring30NI-2000, NI-3000, NI-4000 Hardware Reference GuideIR/Serial Port: Connections and WiringYou can connect up to eight IR- or Ser
Connections and Wiring31NI-2000, NI-3000, NI-4000 Hardware Reference GuideEthernet/RJ-45 Port: Connections and WiringThe following table lists the pin
Connections and Wiring32NI-2000, NI-3000, NI-4000 Hardware Reference GuideEthernet Ports Used By the Integrated ControllerEthernet Port DescriptionsPo
Connections and Wiring33NI-2000, NI-3000, NI-4000 Hardware Reference Guide
5/08 ©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without no
iiNI-2000, NI-3000, NI-4000 Hardware Reference GuideTable of ContentsInput/Output (I/O) Port: Connections and Wiring...
Introduction1NI-2000, NI-3000, NI-4000 Hardware Reference GuideIntroductionNetLinx Integrated Master Controllers can be programmed to control RS-232/4
Introduction2NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-2000 SpecificationsThe front panel LEDs (FIG. 1) are grouped by control type and are
Introduction3NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-2000 SpecificationsDimensions (HWD): • 3.47" x 17.00" x 3.47" (8.81 c
Introduction4NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-2000 Specifications (Cont.)Rear Panel Connectors (Cont.):Relay (Port 4) • Four-chann
Introduction5NI-2000, NI-3000, NI-4000 Hardware Reference GuideNI-2000 Specifications (Cont.)Rear Panel Connectors (Cont.):Ethernet Link/Activity LED
Comments to this Manuals