1. Discharge the static electricity from your body by touching a grounded metal object
and unplug all the connectors from the unit.
2. Remove the three screws by turning them in a counter-clockwise direction and remove
the front faceplate.
3. Align the edges of the card with the internal guide slots and gently slide it in all the way
until the rear edge of the card snap into place.
4. Re-secure the faceplate by inserting the three screws by turning them in a clockwise
direction and securing the front faceplate to the Controller.
5. Re-apply power and other connections as necessary.
Setting the Integrated Controllers’ Starting Card Address
The 8-position CardFrame Number DIP switch on the rear panel sets the starting address
(the device number in the D:P:S specification) for the Control Cards installed in the controller.
The Control Card address range is 1 - 3064.
The factory default CardFrame DIP switch value = 0 (All CardFrame DIP switches in the OFF
position). The formula for setting the starting address is:
(DIP switch value) + Card slot Number (1 - 4) = Card Address
For example:
A DIP switch setting of 00010101:
(0 + 0 + 0 + 96 + 0 + 384 + 1536) + SLOT # (ex:1) = 2017.
A card in slot number 1 = device address 2017.
Set the CardFrame Number DIP switch value is based on the table below.
Cycle power to the unit for approximately 5 seconds. This allows the unit to read the new
device number settings.
Wiring a Power Connection
Use a 12 VDC-compliant power supply to provide power to the Controller via the rear 2-pin
3.5 mm mini-Phoenix connector. Use the power requirements information listed in the
Specifications table to determine the power draw.
The incoming PWR and GND cable from the PSN power supply must be connected to their
corresponding locations within the PWR connector.
• This unit should only have one source of incoming power.
• Using more than one source of power to the Controller can result in damage to the
internal components and a possible burn out.
• Apply power to the unit only after installation is complete.
RS-232/422/485 Wiring Connector Information
FIG. 2 shows the pinout and wiring specification information for the rear RS-232/RS-422/RS-
485 (DB9) Device Ports. These ports support most standard serial mouse control devices
and RS-232 communication protocols for PC data transmission.
The NI-4100 uses Ports 1 - 7.
WARNING: When wiring the 422/485 connections, do NOT use pre-made 9-wire cable or
connect the wire in the cable to any connection that will not be used by the DB9 serial port.
Only use wiring that connects the needed pins.
Ethernet 10/100 Base-T Connector
The RJ-45 Ethernet connector provides 10/100 network connectivity between the panel and
the NetLinx Master (FIG. 3).
Use a standard CAT5 Ethernet cable to provide communication between the Integrated
Controller and external NetLinx devices.
Baud Rate Settings (Program Port DIP Switch)
The Program Port DIP switch is located on the rear of the device. Use this DIP switch to set
the baud rate for the Program Port, according to the settings shown in the following table.
Make sure the baud rate you set matches the baud rate on your PC's NetLinx COM Settings
before programming the unit.
Note: DIP switch 1 activates/deactivates the Program Run Disable Mode. DIP Switches 2,3,
and 4 must remain OFF at all times.
Ethernet Ports Used by the NI-4100
Preparing the NI-4100 for Serial Communication
To establish serial communication with the Controller via the PROGRAM (DB9) port:
1. Use a Serial DB9 cable (i.e. CC-COM Programming Port Cable - not included) to
connect the Controller’s Program port to a DB9 port on a PC.
2. Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc
> NetLinx Studio 2 > NetLinx Studio 2).
3. Select Settings > Master Communication Settings, from the menu bar, to open the
Master Communication Settings dialog box.
4. Click the Communications Settings button to open the Communications Settings
dialog.
5. Click the NetLinx Master radio button (from the Platform Selection section) to indicate
you are working with a NetLinx Master.
6. Click the Serial radio button (from the Transport Connection Option section) to indicate
you are connecting to the Master via a COM port.
7. Click the Edit Settings button (on the Communications Settings dialog) to open the
Serial Settings dialog and set the COM port parameters (used to communicate to the
NetLinx Master).
8. Click OK to close all dialogs and return to the main application.
9. Right-click the Online Tree tab entry and select Refresh System: the Controller
should appear in the Device Tree. If not, verify that the Serial cable is connected
properly, and that the Baud Rate settings on the Controller (set via the Program Port
DIP Switch) match the settings in NetLinx Studio.
Once Serial communication has been established, use NetLinx Studio to configure the
Controller for Ethernet Communication, as described below.
Configuring the NI-4100 for Ethernet Communication
Before continuing, complete the COM port steps above.
1. Use an Ethernet cable to connect the Controller to the LAN to which the PC running
NetLinx Studio is connected.
Note: The NI-x100 Controllers feature an Auto MDI/MDI-X Ethernet port. This provides
the option of using either a standard (straight through), or a crossover Ethernet cable
to communicate with a PC - both cable types will work.
2. Select Diagnostics > Network Address from the menu bar and enter the System,
Device (0 for a Master), and Host Name information.
3. To configure the Address:
• Use a DHCP Address by selecting the Use DHCP radio button, then click the GET IP
button (to obtain a DHCP Address from the DHCP Server), click the SET IP Informa-
tion button (to retain the new address), and then finish the process by clicking the
Reboot Master > OK buttons.
• Use a Static IP Address by selecting the Specify IP Address radio button, enter the IP
parameters into the available fields, then click the SET IP Information button (to retain
the pre-reserved IP Address to the Master), and then click the Reboot Master > OK
buttons to finish the process.
4. Repeat steps 1 - 5 from the previous section, but rather than selecting the Serial
option, choose TCP/IP and edit the settings to match the IP Address you are using
(Static or IP).
5. Click on the Authentication Required radio box (if the Master is secured) and press
the User Name and Password button to enter a valid username and password being
used by the secured Master.
6. Click the OK to close all dialogs and return to the main application.
Onboard WebConsole
NetLinx Masters have a built-in WebConsole that allows you to make various configuration
settings via a web browser on any PC that has access to the Master.
The WebConsole consists of a series of web pages that are collectively called the "Master
Configuration Manager". Refer to the NI Series NetLinx Integrated Controllers WebConsole
& Programming Guide for details on the WebConsole.
Accessing the WebConsole
From any PC that has access to the LAN that the target Master resides on:
1. Open a web browser and type the IP Address of the target Master in the Address Bar.
2. Press Enter to access WebConsole for that Master. The initial view is the WebControl
page.
Additional Documentation
Additional Documentation for the N1-3100 is available at www.amx.com:
• Refer to the NXI-x100 Series Hardware Reference Guide for additional details on
Installation, Upgrading, and Wiring the NI-3100.
• Refer to the NI Series NetLinx Integrated Controllers WebConsole & Programming
Guide for detailed configuration instructions.
Position 12345678
ON position
Value 12 24 48 96 192 384 768 1536
FIG. 2 RS-232/422/485 DB9 (male) connector pinouts
FIG. 3 Layout of Ethernet LEDs
Baud Rate Settings
Baud Rate Position 5 Position 6 Position 7 Position 8
• 9600 bps OFF ON OFF ON
• 38,400 bps (default) OFF ON ON ON
• 57,600 bps ON OFF OFF OFF
•115,200 bps ONONONON
5
4
3
2
1
9
8
7
6
DB9 Serial Port pinouts (male connector)
Pin 2: RX signal
Pin 3: TX signal
PIN 5: GND
Pin 7: RTS
Pin 8: CTS
RS-232
Pin 1: RX -
Pin 4: TX +
PIN 5: GND
Pin 6: RX +
Pin 9: TX -
RS-422
Pin 1: A (strap to 9)
Pin 4: B (strap to 6)
PIN 5: GND
Pin 6: B (strap to 4)
Pin 9: A (strap to 1)
RS-485
SPD - Speed LED lights (yellow)
100 Mbps and turns Off when the
speed is 10 Mbps.
when the connection speed is
L/A - Link/Activity LED lights
(green) when the Ethernet
cables are connected and
terminated correctly.
Ethernet Ports Used
Port type Port # Type
• FTP 21/20 TCP
•SSH (only SSH v2 is supported)22TCP
•Telnet 23 TCP
• HTTP 80 TCP
• HTTPS/SSL 443 TCP
• ICSP 1319 UDP/TCP
• integration! Solutions 10500 TCP