Quick Start Guide
DXLink™ Twisted Pair Transmitters/Receiver
Overview
The DXLink Multi-Format TX and HDMI RX Modules transmit HDMI, audio, and
control over twisted pair cable. (The HDMI TX is discontinued.) The Multi-Format TX
also has an analog video input. DXLink Modules can be set up in one of three ways:
• Endpoint Mode (Switcher) – connect one or more to a switcher with an
integrated Master.
• Endpoint Mode (Standalone) – connect TX/RX pair directly to each other with
one connected to a NetLinx Central Controller via LAN or directly to Controller.
• Extender Mode (Standalone) – connect TX/RX pair directly to each other.
These Modules support InstaGate Pro® and SmartScale® Technology.
The Instruction Manual – DXLink Twisted Pair Transmitters/Receiver contains
complete documentation (including full specifications and supported input and output
resolutions); for details, see www.amx.com.
General Specifications
* A desktop power supply (ENERGY STAR
®
qualified) is provided with each module.
** “Common building” is defined as: Where the walls of the structure(s) are physically
connected and the structure(s) share a single ground reference.
System Setup
The Multi-Format TX (or HDMI TX) and the RX work with a switcher that supports
DXLink Technology for transmission of HDMI (or with a Central Controller) or as a
standalone pair. The Transmitter receives an HDMI signal (or analog video on a
Multi-Format TX) and embedded audio from the source. Both the video and embedded
audio are transported over twisted pair cable to a DXLink Input Board (or connector).
The signal is routed via the DXLink Output Board (or connector) to an RX. On both
Transmitters, stereo audio or digital audio connections are provided as supplemental
audio inputs. The RX also provides a stereo audio output. Both Transmitters and the
Receiver support RS-232 for serial data transfer, USB, IR, and Ethernet.
DIP Switch Toggles – Default OFF
Before installing the units, find the scenario you are using in the table below and set
the DIP switch toggles accordingly. Toggle #4 is reserved for future functionality.
For standalone pair upgrades, set Toggles #1-2-3 to ON and connect one unit to Master.
* Connect ICS LAN port of DXLink unit to network device (e.g., laptop, IP controlled projector,
ICSLan Device). In standalone setup, connect ICS LAN port of other DXLink unit to network.
** In standalone setup using NetLinx control of DXLink serial/IR ports, only one of the DXLink
units should be connected to network (the unit with #1 Toggle enabled).
Grounding
If the system is experiencing problems with delivery of DXLink signals to/from an
Enova DGX Digital Media Switcher or Enova DVX Solution, adding a ground wire from
the TX/RX to the switcher may improve performance. Technically this type of
grounding is only required when a DXLink Transmitter or Receiver is connected to an
ungrounded device, but this added grounding measure can be used at the discretion
of the installer (for instructions, see the product manual).
Mounting Options (Rack Trays and Mounting Brackets)
For details on the four versatile mounting kit options for V Style modules (rack tray,
rack tray with fill plates, surface mount, and pole mount), see www.amx.com.
General Specifications
Approvals CE, UL, cUL, FCC Class A, RoHS
AC Power* • 100 to 240 VAC single phase, 50 Hz to 60 Hz
• 0.6 A @ 115 VAC max.
Power Consumption,
Local 12 V Supplied (max.)
Multi-Format TX 10 W (13.5 V), HDMI TX 9 W,
HDMI RX 18 W
Power Consumption,
Enova DXLink Supplied (max.)
Multi-Format TX 10 W, HDMI TX 9 W,
HDMI RX 15 W
DXLink Power
Important: AMX does not support
use of any other power supplies or
PoE injectors as they may potentially
damage the DXLink equipment.
• Power can be supplied by a DXLink Power
sourcing device such as an Enova DGX 8/16/32
or compatible Enova DVX (3155HD or 2155HD)
or PS-POE-AT-TC (FG423-84) or PDXL-2
(FG1090-170).
• To use PS-POE-AT-TC or PDXL-2 as a power
source, the TX and RX modules require firmware
v1.2.40 for TX and v1.0.80 for RX or later.
• When used in conjunction with the Enova DGX,
use the Enova DGX Configuration Tool located at
www.amx.com/enova to determine the power
requirements of a configuration and whether any
of the DXLink Transmitters or Receivers should
be powered with the local power. The tool
contains instructions on how to use it.
Thermal Dissipation,
Local 12 V Supplied (max.)
Multi-Format TX 34 BTU (13.5 V),
HDMI TX 31 BTU, HDMI RX 61 BTU
Thermal Dissipation,
Enova DXLink Supplied (max.)
Multi-Format TX 34 BTU, HDMI TX 31 BTU,
HDMI RX 51 BTU
Operational Temperature
Storage Temperature
• 32° F to 104° F (0° C to 40° C)
• -22° F to 158° F (-30° C to 70° C)
Operational Humidity
Storage Humidity
• 5% to 85% RH (non-condensing)
• 0% to 90% RH (non-condensing)
Dimensions
5.15 in. (13.08 cm) depth; 8.71 in. (22.12 cm) width;
1.00 in. (2.54 cm) height
Weight / Shipping Weight Approx. 1.1 lb. (0.50 kg) / 2.20 lb. (1.00 kg)
MTBF 381,000 hrs.
Compatible Formats HDMI, HDCP, DVI
(DVI requires conversion cable)
Analog Signal (Multi-Format TX only) RGBHV, RGBS, RGB, Y/Pb/Pr, Y/c, composite
Supported Twisted Pair Cable Types Shielded Cat6, Cat6A, Cat7
Note: For more details and helpful cabling
information, reference the white paper titled
“Cabling for Success with DXLink” at
www.amx.com
or contact your AMX representative.
Supported Twisted Pair Cable Length
Up to 328 ft. (100 m)
Important: DXLink twisted pair cable runs for
DXLink equipment shall only be run within a
common building.**
Compatible Products Enova DGX 8/16/32; most Enova DVX Solutions
FIG. 1 DXLink TX and RX as endpoint solution with compatible DXLink equipment
FIG. 2 DXLink TX and RX as extender solution
Common Scenarios Toggles
Standalone Setup (TX/RX pair direct connection) 1 - 2 - 3
AV signals only OFF - OFF - OFF
AV with Ethernet pass-through to networked device* ON - OFF - OFF
AV with NetLinx control of TX/RX unit and serial/IR ports** ON - ON - ON
AV with NetLinx control of TX/RX unit and serial/IR ports, plus Ethernet
pass-through to network device*
ON - ON - ON
Switcher Setup (TX/RX with Enova DVX/DGX Switcher) 1 - 2 - 3
AV signals only OFF - OFF - OFF
AV with Ethernet pass-through to networked device* ON - N/A - OFF
AV with NetLinx control of TX/RX unit and serial/IR ports OFF - N/A - ON
AV with NetLinx control of TX/RX unit and serial/IR ports, plus Ethernet
pass-through to network device*
ON - N/A - ON
FIG. 3 DIP switch toggles enable/disable special functionality
Destination device
Twisted pair cable
DXLink Receiver
DXLink Transmitter
Source device
DXLink
Input Boards
DXLink
Output Boards
Enova DGX 16
Twisted pair cable
Destination device
DXLink Receiver
DXLink Transmitter
Source device
Receiver
TX or
DIP switch
Multi-Format TX
Comments to this Manuals