Overview
The HPX-1600 HydraPort Retractable Connection Port (FG550-cc) is the first
completely modular, retractable cable connection system built to accommodate the
diverse connection needs of conference and meeting room visitors.
The HPX-1600 is designed to be mounted into a horizontal surface such as a
conference room table or lectern in order to provide connectivity for power,
networking, Audio/Video and control. Specific connectivity is accomplished by
populating the HPX-1600 Base Assembly with various modules.
ATTENTION: Only a professional, AMX-qualified installer should perform this
installation. Installation must conform to all local codes. This product may not
be installed by the end-user.
Product Specifications
The following table lists the components of the (optional) HPX-AC-TK Hydraport
Installation Tool Kit:
The following sections describe the preparation, installation and setup of the
HPX-1600 Hydraport Base Assembly, using the HPX-AC-TK Hydraport Installation
Tool Kit (FG559-90).
Note: Read these instructions in their entirety before beginning the installation. The
installation requires specific steps to be performed in specific order.
CAUTION: This installation kit requires specific woodworking skills. This
installation should be performed by an experienced person, comfortable with
these type of woodworking operations. Improper use of this tool kit may result
in damage to the mounting surface. AMX is not responsible for damage caused
by improper use of this tool kit.
A typical installation will include several of the available modules. Each of these
modules has specific instructions for terminating their rear connections. Refer to the
installation guide for each appropriate module during the installation of the Hydraport
system.
1) Select a Suitable Location For the HPX-1600
Note the space requirements for installing the system (FIG. 1).
The Hydraport system requires a mounting surface from 19mm (.75in) to 50mm
(2.0in) thick.
The Hydraport system requires at least the following amount of space below the
mounting surface to install (see FIG. 1):
383mm (15.08”) height below surface
293mm (11.54”) width
159mm (6.26”) depth
If the system is to be mounted within a column, pillar or other enclosed space
below the mounting surface, please note that final assembly and termination will
require the installer to have access to this space below the mounting surface.
Care should also be taken to ensure that the system does not interfere with the normal
use of the workspace. For example, on a table or work surface, ensure that the
system does not interfere with the user's legs when they are seated at the table.
Note: Even when the system is deployed in the up position, the mounting system and
shields occupy the entire space requirement below the table.
2) Cut the Hole In the Mounting Surface
Use the HPX-AC-TK router template (FG559-90) and a suitable router with ½” arbor to
create the hole in the mounting surface. FIG. 2 provides the hole cutout dimensions for
reference:
1. Carefully measure the tabletop or other mounting surface to locate the desired
position of the Hydraport unit.
2. Apply mounting strips or other appropriate double sided tape to the bottom
surface of the router template, making sure that the rounded edges of the
mounting strips protrude slightly beyond the edges of the template (see FIG. 3).
HPX-1600 Specifications
Dimensions (HWD):
Max above
mounting surface:
9.57" x 10.55" x 4.53"
(243mm x 268mm x 115mm)
Max below
mounting surface:
15.08" x 11.54" x 6.26"
(383mm x 293mm x 159mm)
Min. mounting surface
thickness:
19mm (.75in)
Max mounting surface
thickness:
50mm (2.0in)
Weight:
Base Assembly only: 2 Kg (4.41 lbs)
Typical Installation: 3 Kg (6.61 lbs)
Models Available: International, Black trim (FG550-BL)
International, Silver trim (FG550-SL)
Enclosure Natural finish metal frame with plastic top and bottom covers
moving vertically in a plastic sleeve assembly.
Matt black top cover and trim ring (FG550-BL, FG550-01-
BL) or matt silver top cover and trim ring (FG550-SL,
FG550-01-SL).
Matt black module face plates on all I/O modules.
Rear Connections Included rear connection – IEC 320 C14 Power cord
receptacle (FG550-BL, FG550-SL), Included AC Power Cord
(FG-550-01-BL, FG550-01-SL).
Rear connections for individual modules are routed through
openings in the unit’s bottom cover.
Optional Accessories: HPX-AC-TK Hydraport Installation Tool Kit (FG559-90)
HPX-AC-HSP Hydraport Spring Kit for Heavy Loads
(FG559-42)
Optional HPX-AC-TK Hydraport Installation Tool Kit (FG559-90)
Quantity Description
(1) HPX-AC-TMPLT 559-91 router template
(4) Mounting Strips
Note: The Mounting Strips are manufactured by 3M™. The 3M part number is
“17021P”.
(1) Router bit (Freud 12-128 or Whiteside 1072)
(1) Guide Bushing (Woodcraft 144693)
(1) Lock Nut (Woodcraft 144696)
(1) Installation Guide
FIG. 1 Hydraport System Space Requirements
FIG. 2 Hole Cutout Dimensions
6) Install the System Into the Mounting Surface
Turn the system over and install the unit into the cutout in the mounting surface.
Make sure that all cables from the backside terminations pass through the
cutout.
Note that any fixed cables should already be passed through both the mounting
surface and retaining ring.
7) Install the Retaining Ring
1. Insert the four #6-32 x 1 3/8 retaining screws into the retaining ring.
Note the orientation of the retaining ring. This orientation changes in order to
accommodate the various thicknesses of mounting surfaces (see FIG. 5 on
page 2).
Note the direction of the screw bosses.
For mounting surfaces less than 35mm thick, orient the screw bosses away form
the main assembly (down).
For mounting surfaces greater than 35mm thick orient the screw bosses toward
the main assembly (up).
2. Place the retaining ring over the lower portion of the base assembly and against
the underside of the mounting surface.
If an accessory mounting bracket HPX-AC-MB (FG559-21) is to be used, install
it now by trapping it between the retaining ring and mounting surface
3. Gradually tighten the 4 retaining screws to secure the unit in the mounting sur-
face.
Ensure the unit is properly aligned in the mounting surface.
Torque the retaining screws to approximately 3 in-lbs.
Do not over tighten the screws.
4. After tightening the retaining screws ensure the unit moves smoothly up and
down.
Over tightening the retaining screws can cause the system to bind.
If the system binds, gradually loosen the retaining screws until it operates
smoothly.
8) Install Power Cord (If Required)
If AC power modules are to be used in International models (FG550-BL, FG550-SL),
install a suitable 14AWG power cord into the provided IEC 320 C14 socket.
Fold the power cord back 180 degrees, and secure it to the far side of the bottom
cover using the supplied wire ties. (FIG. 11).
Note: Insure the resulting service loop is tight enough so that it does not rub the
shields when the unit moves up and down.
9) Install Shields
1. Secure the 2 shields to each other using the 8 supplied screws.
2. Ensure that any fixed cables pass through the assembled shield appropriately.
3. Snap the assembled shield onto the lower portion of the mounting sleeve.
Install the 4 additional mounting screws into the top of the shield to secure the shield
to the mounting sleeve
10) Secure Cables
Terminate the backside connections as required for each cable exiting bottom of the
HPX-1600. Secure these cables and the power cable to the 4 tabs provided on the
retaining ring using the supplied wire ties (FIG. 12).
Ensure there is sufficient service loop to allow the system to travel in its full
range of motion.
Avoid excess service loop as this can place significant weight on the sliding and
lifting mechanism and prevent the system from functioning properly.
Ensure the service loop does not catch on the shields or any other obstruction
and is away from users who might kick or snag the cables.
Secure the cables in at least one additional location after they have been
secured to the retaining ring so as to prevent undue stress on the system if the
cables are inadvertently kicked, snagged or pulled.
Note: The socket-outlet (Connection to Mains Power branch circuit) shall be installed
near the equipment and shall be easily accessible.
Additional Documentation
For more detailed installation instructions with additional drawings, please refer to the
HPX-1600 Installation Guide, available to view or download from www.amx.com.
FIG. 10
Inserting the Lift Spring Assembly Into the Bottom Cover
The notch on the Lift Spring Assembly
Notch on Lift Spring Assembly
Slot on Bottom Cover
fits into the slot on the Bottom Cover
Lift Spring Assemblies
Bottom
Cover
Mounting
Sleeve
Clip
FIG. 11 Installing the Power Cord
FIG. 12 Secured Service Loop
Power Cord
AC Power Socket
#4 Plastite screws
(provided)
Retaining Ring
Shields
Mounting Surface
Tabs/Wire Ties (2 on each side)
Cables from bottom
of HPX-1600
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
3/12
©2012 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
93-0550-01 REV: C
Installation Guide
HPX-1600 Retractable Connection Port
page 1 of 4
page 4 of 4
Page view 0
1 2

Summary of Contents

Page 1 - Installation Guide

OverviewThe HPX-1600 HydraPort Retractable Connection Port (FG550-cc) is the first completely modular, retractable cable connection system built to ac

Page 2 - 4) Insert the Modules

3. Use the alignment marks scribed on the template to align the template properly on the mounting surface (FIG. 3). • Note that due to the guide bushi

Comments to this Manuals

No comments