Program Port Connections/Wiring
The NXC-ME260/64 is equipped with two Program ports. One is located on the
front panel and the other is on the rear for easy access. The port on the front
panel is an RS232 (male) connector and the rear port is a grey 5-pin (male)
connector. Use a Programming cable to connect the Program port to your PC's
COM port to communicate with the Master card. Then, you can download
NetLinx programs to the Master card using the NetLinx Studio 2 software
program.
Wiring a power connection
Use a 12 VDC-compliant power supply to provide power to the Master through
the rear 2-pin 3.5 mm mini-Phoenix. Use the power requirements information
listed in the Specifications table to determine the power draw. The incoming
PWR and GND cable from the PSN power supply must be connected to their
corresponding locations within the PWR connector. Refer to the unit’s
instruction manual for more detailed wiring connection information.
RS-232/422/485 wiring connector information
The following table shows the pinout and wiring specification information for the
front panel RS-232 (DB9) Program Port.
RJ-45 Connections
Use a standard CAT5 Ethernet cable to provide communication between the
Master and external NetLinx devices.
Ethernet 10/100 Base-T Connector
The Ethernet cable provides 10/100 network connectivity between the panel
and the NetLinx Master (FIG. 2).
Baud Rate Settings
The Program Port DIP switch is located on the card’s internal circuit board. For
cards installed in modules, you must remove the front panel to access the DIP
switch. Use this internal DIP switch to set the baud rate used by the Program
port for communication. Use this DIP switch to set the baud rate for the
Program Port, according to the settings shown in the following table. Make sure
the baud rate you set matches the baud rate on your PC's NetLinx COM
Settings before programming the unit.
By default, the baud rate is set to 38,400 (bps).
Note: The Program Port DIP Switch is also used to set Program Run Disable
(PRD) mode. The PRD mode prevents the NetLinx program stored in the
Master from running when you power up the NXC-ME260/64.
Note: DIP switch 1 activates/deactivates the Program Run Disable Mode.
DIP Switches 2,3, and 4 must remain OFF at all times.
Setting the Configuration (Program Port) DIP Switch
1. Disconnect the power supply from the rear 2-pin PWR (green) connector.
2. Set DIP switch positions according to the information listed in the
previous Baud Rate Settings table.
3. Reapply power to the unit.
SPE Port Connection/Wiring
Use an RJ-11 cable to connect the NXC-ME260/64 to an AXB-SPE (FG714)
Slave Port Expander. The EXPANSION OUT port on the rear panel of the
NXC-ME260/64 connects to the EXPANSION IN port on the rear panel of the
AXB-SPE. You can daisy chain multiple AXB-SPE's by connecting the
EXPANSION OUT on the primary AXB-SPE to the EXPANSION IN port on the
secondary. The connecting RJ-11 cable should not exceed 6" in length.
Repeat this process to connect up to nine AXB-SPE's.
Preparing the ME260-64 for Serial Communication
1. Launch NetLinx Studio 2.x (default location is Start > Programs > AMX
Control Disc > NetLinx Studio 2 > NetLinx Studio 2).
2. Select Settings > Master Communication Settings, from the Main
menu, to open the Master Communication Settings dialog box.
3. Click the Communications Settings button to open the Communications
Settings dialog.
4. Click the NetLinx Master radio button (from the Platform Selection
section) to indicate you are working with a NetLinx Master.
5. Click the Serial radio button (from the Transport Connection Option
section) to indicate you are connecting to the Master via a COM port.
6. Click the Edit Settings button (on the Communications Settings
dialog) to open the Serial Settings dialog and set the COM port
parameters (used to communicate to the NetLinx Master).
7. Click the OK button three times to return to the main application.
8. Right-click the Online Tree tab entry and select Refresh System.
9. Assign a System Value by using Diagnostics > Device Addressing from
the Main menu.
10. Enable the Change System selection by clicking on it and then enter the
current and new System values.
11. Click the Change Device/System Number button and when finished
click Done.
12. Select Tools > Reboot the Master Controller to access the Reboot the
Master dialog, then click Reboot to restart the Master and incorporate
any changes.
13. Once the dialog replies with "Reboot of system complete", click Done and
then click the OnLine Tree tab in the Workspace window to view the
devices on the System.The default System value is one.
14. Right-click on the Empty Device Tree/System entry and select Refresh
System to re-populate the list.
Configuring the ME260-64 for Ethernet Communication
Before continuing, complete the COM port steps above.
1. Connect an Ethernet cable to the unit’s rear Ethernet connector.
2. Select Diagnostics > Network Address from the Main menu and enter
the System, Device (0 for a Master), and Host Name information.
3. To configure the Address:
Use a DHCP Address by selecting the Use DHCP radio button, then click
the GET IP button (to obtain a DHCP Address from the DHCP Server),
click the SET IP Information button (to retain the new address), and then
finish the process by clicking the Reboot Master > OK buttons.
Use a Static IP Address by selecting the Specify IP Address radio
button, enter the IP parameters into the available fields, then click the
SET IP Information button (to retain the pre-reserved IP Address to the
Master), and then click the Reboot Master > OK buttons to finish the
process.
4. Repeat steps 1 - 5 from the previous section but rather than selecting the
Serial option, choose TCP/IP and edit the settings to match the IP
Address you are using (whether Static or IP).
5. Click on the Authentication Required radio box (if the Master is
secured) and press the User Name and Password button to enter a
valid username and password being used by the secured Master.
6. Click the OK button three times to return to the main application.
Program Port Connector Pinouts (RS232)
Pin Signal Function
1 N/A Not used
2 RXD Receive data
3 TXD Transmit data
4 DTR Not used
5 GND Signal ground
6 DSR Not used
7 RTS Request to send
8 CTS Clear to send
9 N/A Not used
FIG. 2 Layout of Ethernet LEDs
Baud Rate Settings
Baud Rate Position 5 Position 6 Position 7 Position 8
9600 bps OFF ON OFF ON
38,400 bps
(default)
OFF ON ON ON
57,600 bps ON OFF OFF OFF
115,200 bps ON ON ON ON
12345
678
9
SPD - Speed LED lights (yellow) when
and turns Off when the speed
is 10 Mbps.
the connection speed is 100 Mbps
L/A - Link/Activity LED lights
(green) when the Ethernet
cables are connected and
terminated correctly.