Installation Guide
MET-ECOM Metreau
Entry Communicator
Overview
The MET-ECOM Metreau Entry Communicator (FG2180-01-cc) can be placed at
entry points of homes, condos and hotels to provide audio communications with
anyone at a door or gate - all over IP. Any AMX Modero intercom-enabled touch panel
can interface with the Entry Communicator and allow residents to open doors, gates
and more.
Refer to the Metreau Entry Communicators Operation/Reference Guide (available
online at www.amx.com) for additional installation details and instructions on using the
Configuration Manager, using the full-duplex intercom, and NetLinx Programming
information.
Product Specifications
Rear Panel Components
FIG. 2 shows the location of the rear panel components for the MET-ECOM.
FIG. 1
MET-ECOM Metreau Entry Communicator
MET-ECOM Specifications
Power: PoE powered – no local Power Supply needed
IEEE 802.3af Compliant
Front Panel Components: Integrated Color Video Camera
Speaker
Dual Color LED Status Bar: (Yellow/ Red) can be used to
provide feedback, to attract attention for action, or as
general indicator.
Pushbutton (Doorbell)
Microphone
Integrated Color Video
Camera:
QVGA 320 x 240
Supports Motion JPEG (MJPEG) and H.263 codecs.
Horizontal viewing angle: 46°
Vertical viewing angle: 33°
Adjustable Viewing Angle for Camera: 42°
Speaker: 8 Ohm, 2W
80dB SPL (sound pressure level at 1 meter)
Meets G.711 sound standard
Microphone: -40 dB sensitivity, built-in echo cancellation
(telephone quality)
Full duplex communication
VoIP Telephony
Rear Panel Components: Camera Viewing Angle Adjustment
Ethernet Port - 10/100 Ethernet with PoE. LEDs show
communication activity, connection status, speeds, and
mode information:
SPD (speed) - Green LED lights On when the connection
speed is 100 Mbps and turns Off when the speed is 10
Mbps.
L/A (link/activity) - Orange LED lights On when the
Ethernet cables are connected and terminated correctly,
and blinks when receiving Ethernet data packets.
ID/Reset pushbutton: Push to set the NetLinx ID (Device
only) assignment for the device. Push and hold for at least
10 seconds to reset to factory default settings.
Status LED: Green LED provides an indication of both the
system status and communication status with the target
Master. 1 blink every 5 seconds indicates there is
currently active communication between the Metreau unit
and a target Master.
2 Multi-Purpose I/Os (5V): 2-channel binary I/O ports for
contact closure with each input being capable of voltage
sensing. Input format is software selectable with
interactive power sensing for IR ports.
Pushbutton (Doorbell)
Speaker
Video Camera
Microphone
Dual Color LED Status Bar (Yellow / Red)
MET-ECOM Specifications (Cont.)
Rear Panel Components
(Cont.):
2 Low Voltage Relays (1A/24VDC contact): 2-channel
single-pole single throw relay ports with each relay being
independently controlled and supporting up to 2
independent external relay devices.
Dimensions (HWD): 5.364” x 3.594” x 1.559”
(13.62 cm x 9.13 cm x 3.96 cm)
Weight: 0.90 lbs (0.408 kg)
Environmental: Operating Environments: 32º - 104º F (0º - 40º C)
Storage Environments: 22º - 140º F (-30º - 60º C)
Heat Dissipation (Typical): 20.5 BTU/hr
Note: The MET-ECOM is weather-resistant and is ideal for
placement in residential outdoor entryways or next to doors
to notify residents that visitors have arrived.
However, please consider the surrounding environment and
avoid installing the unit in a location that will leave the
MET-ECOM directly exposed to the elements. In particular,
avoid prolonged exposure to water.
Mounting: The MET-ECOM is installed in several ways:
4 screws for hard surface mounting
2 expansion clips for pressure mounting
Using the optional Surface Mount Box
Colors Available: Black MET-ECOM-BK (FG2180-01-BK)
White MET-ECOM-WH (FG2180-01-WH)
Polished Brass MET-ECOM-PB (FG2180-01-PB)
Antique Brass MET-ECOM-AB (FG2180-01-AB)
Stainless Steel MET-ECOM-SS (FG2180-01-SS)
Brushed Pewter MET-ECOM-BP (FG2180-01-BP)
Included Accessories: Installation Kit (KA2180-01) - includes front mount flange,
4 installation screws (#4-40 x 3.12), 2 Phoenix connectors
(female, 3.5mm) and a Ferrite clip.
Other AMX Equipment: PS-POE-AF Power-over-Ethernet (PoE) power supply
(FG423-80)
NXA-ENET24 Managed Ethernet Switch
(FG2178-60)
NXA-ENET24PoE Managed Ethernet Switch, Power Over
Ethernet (FG2178-61)
Conduit Box Assembly (FG039-12)
SMB-MET-ECOMS-B/P Surface Mount Box - Black or
Primed for painting (FG039-14-B/P)
Certifications: FCC Class B
•CE
IEC60950
•RoHS
FIG. 2 Metreau Entry Communicator (rear panel)
Camera Viewing
Ethernet Connection
2 Multi-Purpose I/Os (5V)
2 Low Voltage Relays
Mounting Slots
(2 on each side)
Mounting Clip
ID/Reset pushbutton
STATUS (green LED)
Angle Adjustment
(1A/24VDC Contact)
Page view 0
1 2

Summary of Contents

Page 1 - MET-ECOM Metreau

Installation GuideMET-ECOM Metreau™ Entry CommunicatorOverviewThe MET-ECOM Metreau Entry Communicator (FG2180-01-cc) can be placed at entry points of

Page 2 - Mounting Specifications

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).2/12©2012 AMX. All rights reserved. AMX and the

Comments to this Manuals

No comments