Novara AxLink KeyPads
23
Novara ControlPads & KeyPads
Daisy-Chaining KeyPads (AxLink only)
To daisy chain the KeyPads via AxLink, both KeyPads should be connected to the AxLink, as shown in FIG. 9.
Use screened cable to link to units.
The maximum cable length between panels should not exceed 50’ (15.24 m).
Daisy-chaining via Serial connection is not supported.
RS-232 Connections
FIG. 9 Daisy-Chaining KeyPads
FIG. 10 RS232 Control - Connections
Power Supply
GND
AXM
AXD
Power Supply
From KeyPad
RX
TX
Gnd
External Controller
Feedback
TX
RX
Gnd