Installation Guide
CSG SIP Communications Gateway (CSG-500/544/580)
ATTENTION: READ THIS FIRST!
For more detailed installation, configuration, programming, and operating
instructions, refer to the CSG SIP Communications Gateway Instruction Manual
available on-line at www.amx.com.
FIG. 1 CSG SIP Communications Gateway (displaying CSG-544)
Overview
The CSG SIP Communications Gateway (FIG. 1) is a stand alone Private Branch
Exchange (PBX) which can also function as a VoIP ATA, or VoIP gateway. It has
eight analog ports that can be configured (via modules) as Foreign Exchange
Office (FXO) or Foreign Exchange Station (FXS) ports.
The CSG enables you to transform an intercom-enabled Modero Touch Panel
into a full-featured IP phone. With the CSG and an intercom-enabled Modero
Touch Panel you can make and receive local, long distance, and international
phone calls, and have access to phone features like call waiting, caller ID, call
forwarding, call queuing, and voice mail. The CSG supports AMX Session
Initiated Protocol (SIP)-enabled touch panels—such as the MVP-8400i,
MVP-5200i, NXD-1000Vi, NXD-700Vi, and NXD-500i—and the MET-ECOM
Metreau Entry Communcator, as well as 3rd party IP phones.
Specifications
Installing the Hardware
CAUTION!
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication
wiring for network connections.
1. Connect an Ethernet cable to the Network port.
2. Connect the provided power supply to the unit’s DC connector. The unit
immediately receives power once you connect a power source to it.
3. When the unit completes the boot process, the left-most eight LEDs
indicate how the analog ports are configured. A red light indicates the port
is FXO, and a green light indicates the port is FXS. If the light for a port is
off, the port is not installed.
Note: The analog port configuration is selected when you purchase your CSG
unit.
4. Connect telephones to the analog ports that are configured as FXS ports
and connect phone lines to the analog ports that are configured as FXO
ports. If you are using the CSG-500, you can skip this step.
WARNING!
If you are using the CSG-544, do NOT connect analog ports 1-4 to a phone line.
Since both the FXS port and the phone line supply power, the hardware could
sustain damage. This damage is not covered under the AMX standard warranty.
Instructions for Wall Mounting
1. Select the area to mount the CSG unit. The unit should be mounted at or
below eye level to properly view the LEDs.
2. Line up one of the surface mounting brackets with the two holes on one
side of the CSG. Install two #4-40 X .250 PPH screws into the holes in the
bracket to secure the bracket to the CSG.
3. Repeat step 2 to attach the second bracket to the other side of the unit.
4. Affix one screw to the wall.
Leave approximately 1/4-inch of the screw
protruding from the wall to allow the head of the screw to slide into the
settings on the mounting bracket, mounting the unit to the wall.
5. Repeat step 4 to attach the second bracket to the wall.
Understanding the LEDs
There are 14 LEDs on the front panel of the CSG. The eight LEDs corresponding
to the analog ports on the rear panel indicate the type of interface installed. The
following table explains the definition of each LED and its color representation:
CSG Specifications
Dimensions 1.74” x 11.45” x 5.44” (4.41 cm x 29.09 cm x 13.82 cm)
Weight 2.25 lbs. (1.02 kg)
Enclosure Metal with black matte finish
Power
Requirements
Constant current draw: 2.6 A @ 12 VDC
Memory 8MB on board serial Flash memory
64MB 16-bit parallel SDRAM
Certifications FCC (Class A), CE, IEC60950, and RoHS
Operating/
Storage
Environment
Operating Temperature: 0° C (32° F) to 40° C (104° F)
Operating Humidity: 5% to 85% RH Non-Condensing
Storage Temperature: -20° C (-4° F) to 70° C (158° F)
Storage Humidity: 0% to 85% RH Non-Condensing
Front Panel Components:
Power LED Indicates whether the unit is turned on and receiving power.
Network LED Indicates whether a network cable is connected and the speed of
the network.
IP Phones
LEDs
Indicates whether the corresponding link is connected and the
speed of the link.
Analog LEDs Indicates whether the analog port is installed and the type of port
(FXO/FXS) installed. (Not available on all models.)
Rear Panel Components:
Power
connector
5.1mm OD, 2.1mm pin, 12V 3.0A center positive
Configuration
Reset Switch
Resets the current configuration to the factory default when
pressed continuously during the boot process.
Console port 1 RJ45 port for console (craft) port serial control
Network port 1 RJ45 10/100baseT port for a general (WAN) connection
IP Phones
ports
4 RJ45 10/100baseT ports for IP phone connections
Analog ports 8 RJ11 ports: 4 for FXO and 4 for FXS connections (CSG-544
only)
8 RJ11 ports for FXO connections (CSG-580 only)
Note: The CSG-500 does not use analog ports.
CSG Specifications (continued)
Compatible
Devices
MVP-8400i
NXD-500i
NXD-700Vi
NXD-1000Vi
MVP-5200i
MET-ECOM Metreau Entry Communicator
Included
Accessories
PSN3.0, Power Supply, 3.0A, 12.0VDC (FG423-31)
CSG SIP Communications Gateway Installation Guide
(93-2182-01)
2 Surface mounting brackets (62-2182-04)
4 #4-40 X .250 PPH screws (80-0112)
Other AMX
Equipment
DIN Rail Mounting Bracket (FG532-06)
LED Definitions
LED Color Description
Power Blue (pulsing) On when the unit boots up after the bootload process
has completed. The LED pulses at a rate which is
proportional to the processor load.
Network Off No line is connected or the interface is inactive.
Green
(flashing)
Link is up at 100Mbps. LED flashes at 1/10 second
intervals as traffic is detected.
Red (flashing) Link is up at 10Mbps. LED flashes at 1/10 second
intervals as traffic is detected.
Page view 0
1 2

Summary of Contents

Page 1 - Installation Guide

Installation GuideCSG SIP Communications Gateway (CSG-500/544/580)ATTENTION: READ THIS FIRST!For more detailed installation, configuration, programmin

Page 2 - Setting Up Your System

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).12/09©2009 AMX. All rights reserved. AMX and the

Comments to this Manuals

No comments